The battery thermal management system (BTMS) has the functions of cooling the battery, heating the battery and mitigating battery thermal runaway. It can control the temperature of the battery pack at 25~40℃, and the temperature difference between single cells is less than 5℃.
Lithium-ion batteries are very sensitive to temperature. When the temperature is below 0°C, the battery is prone to problems such as aging and capacity fading.
For example, the electronic and ionic conductivity of lithium iron phosphate batteries widely used in energy storage power stations drops significantly at low temperatures. .
1. Lithium-ion battery thermal management technology
As the mainstream battery in the global power battery, energy storage battery and consumer battery fields, lithium-ion batteries have always attracted much attention in the development of their thermal management technology.
Early lithium-ion battery thermal management systems were relatively simple, mainly cooling through natural convection of air, that is, passive air cooling. Later, fans were added to speed up the air flow or cold air troughs were used to cool the air in advance, that is, active air cooling.
The cooling effect was improved, but the noise was loud and the temperature uniformity was not good.
To solve this problem, researchers have invented liquid cooling technologies, including cold plate liquid cooling and immersion liquid cooling. Among them, the cooling plate liquid cooling technology is relatively mature and has good cooling effect in battery liquid cooling systems , but it is prone to problems such as coolant leakage, thus causing safety hazards.
Immersion liquid cooling is a cooling technology that has developed rapidly in recent years. The cooling effect is obvious, but it requires high coolant.
Phase change material cooling and thermoelectric cooling technology are new cooling technologies developed in recent years. They have no moving parts and are simple in structure, but have low cooling efficiency.
Overall, there are advantages and disadvantages to current cooling technologies. Generally, it is necessary to combine two or more cooling technologies for composite cooling of batteries. The above lithium-ion battery cooling technologies are explained in more detail below.
2. Air cooling technology
Air cooling is generally divided into two types: natural cooling and forced cooling. The air flow is used to take away the heat generated by the battery and then cool the battery. It has the advantages of simple structure, low cost and no pollution.
Natural cooling is a passive cooling method that often only requires the design of cooling air ducts. It was widely used in early lithium-ion electric vehicles. However, natural air cooling is difficult to meet its power battery cooling needs.
Compared with natural cooling, the forced air cooling effect is improved, but due to the addition of fans and other radiator equipment, noise and energy consumption will also increase. The air flow channel determines the air flow direction and heat transfer method. The cooling performance of air-cooled batteries can be improved by adjusting the shape of the air flow channel.
There are two types of air flow patterns in the air cooling system: serial ventilation and parallel ventilation. Among them, the parallel ventilation of air-cooled energy storage batteries has better temperature uniformity and cooling performance. In addition, battery layout is also an important factor affecting cooling performance.
Currently, in the field of electric flight equipment, air cooling is still chosen as the primary cooling technology. Compared with liquid cooling technology, air cooling technology is lighter in weight, does not increase the weight burden of flight equipment, and consumes less energy.
3. Liquid cooling technology
Liquid cooling is a cooling technology that uses liquid as the cooling medium and uses the phase change or flow of the coolant to exchange heat with the heating components of the battery system. It has the advantages of fast heat dissipation and high cooling efficiency.
It is generally divided into direct liquid cooling and indirect liquid cooling. The coolant of direct liquid cooling is in direct contact with the heating device, such as the representative immersion liquid cooling.
The coolant of indirect liquid cooling does not have direct contact with the heating device, but flows in specific components to indirectly cool the battery, such as cooling plate liquid cooling.
Cooling version liquid cooling
The development of cooling plate liquid cooling technology is relatively mature. Compared with liquid air energy storage technology, its cooling effect is significantly improved, and the cooling plate material is generally aluminum and aluminum alloy, and the cost is low.
At present, research on cooling plate liquid cooling systems mainly focuses on the optimization of cooling plate structure, fluid flow distribution, coolant channel geometry and parameters, aiming to further simplify the manufacturing process and enhance temperature uniformity and cooling performance. Here are Top 10 manufacturers of liquid cooling products in China.
In recent years, regarding the optimization strategy of cooling plate liquid cooling technology, the optimization focus has mainly focused on the coolant channel structure and the coolant flow direction.
Through numerical simulation, it was found that the pressure drop of the new secondary flow serpentine liquid-cooled plate is significantly lower than that of the traditional liquid-cooled plate, which saves pump power.
As the coolant flow rate increases, the maximum temperature and maximum temperature difference of the liquid-cooled plate increase. all gradually decreased. After the flow rate exceeds 0.4m/s, the temperature and the maximum temperature difference remain basically unchanged, and the maximum temperature difference can be guaranteed not to exceed 4.5°C.
Numerical simulation results show that the cooling channel width is 3mm and the vertical distance from the center to the side length of the regular hexagonal aluminum block is 6.8mm, which are the best structural parameters.
The maximum temperature difference under these parameters does not exceed 4.1℃, and when the coolant is in the opposite direction The direction of flow in adjacent honeycomb liquid cooling plates has a better temperature equalization effect.
The above-mentioned research shows that the contact area between the coolant and the battery can be increased through reasonable coolant channel structure design, thereby regulating the heat dissipation effect. At the same time, the flow direction of the coolant is also crucial to temperature uniformity.
At present, cooling plate liquid cooling technology has been successfully used in fields such as energy storage power stations and electric vehicles.
Combined with the above analysis, it can be seen that the cooling plate liquid cooling technology has achieved good commercial applications, but in order to make full use of space or enhance the heat dissipation effect, the shape of the cooling plate needs to be reasonably designed according to the shape of the battery.
Generally speaking, cooling plate liquid cooling is a relatively effective cooling technology for most application scenarios. Its key component, the cooling plate, is generally composed of heat conductive materials such as copper and aluminum.
The cost is not too high and is suitable for use in electric vehicles. Or other equipment with higher demand for cooling effect. You can click Liquid cooling vs air cooling – who is more suitable for energy storage system to get more information.
Immersion liquid cooling technology
Immersion liquid cooling technology means that the battery and heating components are directly immersed in insulating coolant, eliminating the need for fans and other radiators, reducing energy consumption and noise. It is a battery cooling technology with better temperature equalization effect.
Commonly used immersion liquid cooling fluids include insulating oil and fluorinated fluid, which are relatively expensive. Due to the presence of coolant, the weight and volume of the immersed liquid cooling system are relatively large and are not suitable for use in mobile electric vehicles.
Since energy storage power stations have low volume requirements for battery thermal management systems and generally do not need to be moved, immersed liquid cooling technology is more suitable.
Relevant reports indicate that battery energy storage systems using immersed liquid cooling can ensure battery operation. The average temperature rise in the battery does not exceed 5℃, and the temperature difference between single cells does not exceed 2℃, which can effectively extend the service life of the energy storage power station and improve safety.
The results show that increasing the immersion depth can expand the contact surface area, improve the heat transfer coefficient and cooling effect.
Compared with the case of natural air cooling, the maximum temperature and maximum temperature difference of the battery module were reduced by 32.4% and 75.3% respectively. The maximum temperature difference was 1.23°C. The cooling performance of BTMS was greatly improved.
Compared with cooling plate liquid cooling technology, immersion liquid cooling technology has a significant temperature equalization effect, but it also places higher requirements on the insulation of the coolant and the overall design of the battery thermal management system.
Judging from the current application of immersed liquid cooling technology, immersed liquid cooling has been widely recognized and may become the mainstream cooling technology for large energy storage power stations in the near future.
However, the cost of immersion liquid cooling is relatively high, making it difficult to achieve wide-scale application in electric vehicles and small electronic devices.
For some high-end models with higher cooling requirements, immersion liquid cooling technology may be used. At present, immersion liquid cooling technology is still in the initial commercialization stage.
Here are Best top 10 energy storage liquid cooling host manufacturers in the world.








+86 – 18925002618